BF = (Tβ³ Γ Wβ³ Γ Lβ²) Γ· 12 β standard board feet formula
π Unit Converter
Construction-specific unit conversions
βοΈ Excavation & Earthworks
Excavation volume, backfill, spoils & hauling
Please fill in the required fields.
Swell factors: typical earthwork values (bank β loose). Backfill assumes excavated soil returned & compacted β bank volume. Verify soil class on site.
π Roofing Estimator
G.I. sheets, purlins & tek screws
Please fill in the required fields.
Effective coverage: rib-type β 1.00m, corrugated β 0.70m (1Β½ corrugation side lap), 0.25m end lap. Screws β 4 per m width per purlin line. Verify with your supplier's actual profile.
π Rebar Splicing Calculator
Lap splice length β NSCP 2015 Sec. 425
Please fill in the required fields.
Ref: NSCP 2015 Sec. 425.4.2 (development), 425.5.2 (tension lap A=1.0ld / B=1.3ld), 425.5.5 (compression lap). Normal-weight concrete, uncoated bars. Estimate only β always follow the lap lengths on your sealed structural plans.
π¦ Slab Type Calculator
One-way vs two-way slab by span ratio
Please fill in both span lengths.
One-way: slab bends mainly along the short span β main bars one direction. Two-way: bends in both directions β main bars both ways. Final slab thickness & reinforcement are the structural engineer's design.
π References & Standards
Sources behind every formula in this app
Fajardo β Simplified Construction Estimate
Max B. Fajardo Jr., 3rd Edition. Source for CHB & mortar (Table 1-7), concrete proportions (Table 1-3), and plastering works. The standard estimating reference in Philippine practice.
PNS 49:2020
Philippine National Standard for steel bars for concrete reinforcement. Defines grades (230/280/420/520 MPa β ASTM 33/40/60/75), nominal mass per metre, sizes (8β50mm), standard lengths (6.0β12.0 m) and Β±6% mass tolerance.
NSCP 2015
National Structural Code of the Philippines (ASEP). Governs structural design β concrete classes, reinforcement, development & lap lengths. Always size structural members per a licensed engineer's design.
NSCP 2015 β lap splices (Sec. 425)
Tension development ld (simplified, 425.4.2.3): db β€ 20mm β ld = fyΒ·Οt β (2.1Ξ»βf'c) Γ db; db > 20mm β Γ·1.7 (cover/spacing met) or Γ·1.4 / Γ·1.1 otherwise. Οt = 1.3 top bars. Tension lap: Class A = 1.0 ld, Class B = 1.3 ld, min 300mm. Compression lap: 0.071Β·fyΒ·db (fy β€ 420), Γ1β if f'c < 21 MPa, min 300mm.
Slab type rule (NSCP / ACI practice)
Span ratio L2 Γ· L1 β₯ 2 β one-way slab (bends along short span). Ratio < 2 β two-way slab (bends both directions). Screening rule for analysis method β final design by the structural engineer.
PD 1096
National Building Code of the Philippines. Rule VII / VIII β stair geometry: max riser 200mm, min tread 250mm, comfort rule R+T β 430β460mm.
BP 344
Accessibility Law. Ramp design: max slope 1:12, min width 1.20m, level landings every 6.0m of run.
Steel unit weight formula
kg/m = DΒ² β 162 (D in mm). Matches PNS 49 nominal mass. Used as fallback for any size not in the standard table.
CHB wall reinforcement (Fajardo)
Bar length per sq.m. of wall β vertical: 2.93 (@0.40m), 2.13 (@0.60m), 1.60 (@0.80m); horizontal: 3.30 (every 2 layers), 2.15 (every 3), 1.72 (every 4). Tie wire: #16 G.I., 1 roll = 45 kg β 53 m/kg, est. 0.40m per intersection.
Earthwork swell factors
Typical bankβloose bulking: sand/gravel +12%, common earth +25%, clay +32%, blasted rock +50%. Compacted backfill assumed β bank volume. Always confirm soil classification on site.
Roofing coverage (typical PH profiles)
Rib-type long span β 1.00m effective width, cut to slope length. Corrugated G.I. β 0.70m effective (1Β½ corrugation side lap), 0.25m end lap. Slope area = plan area Γ· cos(pitch). Profiles vary by manufacturer β verify with your supplier.
This app gives quantity estimates to speed up take-offs. It does not replace structural design, detailed engineering, or your approved plans.